  ac/dc converte r li120 series 201 4 .02.25- a /0 page 1of 3 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation 120w, ac-dc converter features z universal input range:85~264vac/120~370vdc z ac and dc all in one (input from the same terminal) z low standby power consumpt ion, high efficiency, 3000vac safe isolation z low ripple and noise z protection of input under-voltage, output short circuit, output over-current, output over-voltage over-temperature protection, and remote control z perfect emc performance, and eft, surge meet level 4 z meet iec61000, ul60950and iec60950 standards li120---- 120w converter offered by mornsun. it features cost-effective, standard rail mounting, energy efficient . it offers stability and high noise immunity for indust rial control equipment , machinery and other harsh environments of industrial equipment . the converter is small, light weight, compact structure, standard rail (35mm) installation and save a lot of space for customers. selection guide certification model output power nominal output voltage and current(vo/io) efficiency (230vac, %/typ.) max. capacitive load( f) ul/ce (pending) LI120-10B24 120w 24v/5a 92 4700 input specifications item operating conditions min. typ. max. unit input voltage range ac input 85 -- 264 vac dc input 120 -- 370 vdc input frequency 47 -- 63 hz input current 115vac -- -- 1.5 a 230vac -- -- 0.75 inrush current 115vac -- 35 -- 230vac -- 70 -- power factor 115vac -- 0.98 -- -- 230vac -- 0.96 -- input under-voltage protection start-up voltage ac input 76 -- 83 va c shutdown voltage ac input 67 -- 75 output specifications item operating conditions min. typ. max. unit output voltage accuracy -- -- 1 % linear regulation full load -- -- 0.5 load regulation -- -- 1 output ripple & noise* 20mhz bandwidth (peak-peak value) -- -- 100 mv temperature drift coefficient -- 0.03 -- %/ c stand-by power consumption -- -- 0.75 w short circuit protection continuous, self-recovery over-current protection 110-150% io, start protecting after 3 seconds, and auto recovery over-voltage protection overvoltage restart over-temperature protection over-temperature shutdown , and auto recovery min. load 0 -- -- % start-up time -- -- 1500 ms
ac/dc converte r li120 series 201 4 .02.25- a /0 page 2of 3 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation hold-up time 115vac -- 25 -- 230vac -- 25 -- note: * rely test method is adopted test the ripple and noise, please see ac-dc converter application notes for specific operation methods. general specifications item operating conditions min. typ. max. unit isolation voltage input-output test time: 1min 3000 -- -- va c input- 1500 -- -- output- 500 -- -- operating temperature -25 -- +70 c storage temperature -25 -- +85 storage humidity -- -- 95 %rh switching frequency -- 100 -- khz power derating +55 to +70 2.5 -- -- %/ c safety standard iec60950/en60950/ul60950 safety-regulated certification en60950/ul60950 pending safety class class i hot plug unavailable mtbf mil-hdbk-217f@25 c > 300,000 h physical specifications casing material heat-resistant plastic (ul94-v0) and metal package dimensions 35.00*125.00*112.70 mm (w*h*d) weight 56020 g cooling method natural cooling emc specifications emi conducted disturbance cispr22/en55022, class b radiated emission cispr22/en55022, class b ems electrostatic discharge iec/en61000-4-2 contact 6kv/air 8kv perf. criteria b radiation immunity iec/en61000-4-3 10v/m perf. criteria a eft iec/en61000-4-4 4kv perf. criteria b surge immunity iec/en61000-4-5 2kv/4kv perf. criteria b conducted disturbance immunity iec/en61000-4-6 10 vr.m.s perf. criteria a immunity for power frequency magnetic field iec/en61000-4-8 10a/m perf. criteria a immunities of voltage dip, drop and short interruption iec/en61000-4-11 0%-70% perf. criteria b product characteristic curve -25 0 55 70 100 25 62.5 100 80 100 85 264 20 40 60 note: when input dc, vdc=1.414*vac-20. ambient temperature( ) temperature derating graph output power percentage(%) input voltage: 100-264vac input voltage derating graph output power percentage(%) note: inp ut volt age sh ou ld be derated ba sed on temperature d eratin g when it is 85-10 0va c. input voltage vac ambient temperature:25
ac/dc converte r li120 series 201 4 .02.25- a /0 page 3of 3 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation LI120-10B24 80 82 84 86 88 90 92 94 96 98 100 85 100 115 150 180 200 230 264 efficiency(%) input voltage(v) efficiency vs input voltage (full load) LI120-10B24 70 75 80 85 90 95 100 10 20 30 40 50 60 70 80 90 100 efficiency(%) output current percentage(%) efficiency vs output load(vin=230vac) design reference 1. typical application circuit ac(l) +vo -vo ac(n) ac(n) rl ac(l) +c trl -ctrl fig. 1: typical application circuit ac(l) +vo -vo ac(n) ac (n ) rl ac (l) +c trl -ctrl external voltage single fig. 2: remote control applications circuit *note: external voltage single range 4.5 ~ 12.5vdc realize the power off, the single disappears and recovery 2. for more information please find the application notes on www.mornsun-power.com dimensions and recommended layout note: 1. packing information please refer to 'product packing information'. packing bag number: 58220028; 2. unless otherwise specified, data in this datasheet should be tested under the conditions of ta=25 c, humidity<75% when inputting nominal voltage and outputting rated load; 3. all index testing methods in this datasheet are based on our company?s corporate standards; 4. the performance indexes of the product models listed in this manu al are as above, but some inde xes of non-standard model produc ts will exceed the above-mentioned requirements, and please dire ctly contact our technician for specific information; 5. we can provide product customization service; 6. the product specification may be change d at any time without prior notice. mornsun guangzhou science & technology co., ltd. address: no. 5, kehui st. 1, kehui develo pment center, science ave., guangzhou scienc e city, luogang district, guangzhou, p. r. china tel: 86-20-38601850-8801 fax: 86-20-38601272 e-mail: info@mornsun.cn


▲Up To Search▲   

 
Price & Availability of LI120-10B24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X